防火卷簾門分隔控制要求標準
在商層建筑中和大型防火卷簾門是不可或缺的防火設施,主要用來隔離較大空間成防火區,有效分隔各層區域的功能。防火卷簾門除了可以當普通門使用外,還有防火、隔煙、防止火勢蔓延、保護人員疏散的特別功能。卷簾門廠家為您整理防火卷簾門分隔控制要求,如下慢慢講來。
In commercial buildings and large shopping malls, fire-resistant rolling shutter doors are indispensable fire prevention facilities, mainly used to isolate larger spaces into fire zones, effectively separating the functions of each floor area. In addition to being used as a regular door, fireproof rolling shutter doors also have special functions such as fire prevention, smoke isolation, preventing fire spread, and protecting personnel evacuation. The rolling shutter door manufacturer has compiled the requirements for the separation control of fireproof rolling shutter doors for you. Let's take the time to explain them as follows.
根據現場需要在防火卷簾門電控箱上設置
Set up on the electrical control box of the fireproof rolling shutter door according to on-site needs
在高層建筑中,超級防火帷幕的有效防火分隔區域的選擇和布局成為超級防火帷幕能否收獲其有效防火功能的關鍵。
In high-rise buildings, the selection and layout of effective fire separation areas for super fire curtains become the key to whether super fire curtains can achieve their effective fire prevention functions.
避免影響生活上下兩層連為防火區
To avoid affecting daily life, connect the upper and lower floors as a fire zone
需要在不影響正常生活和有效的防火隔離之間取得平衡。一般來說,高層建筑均設有上下連通走廊、開敞樓梯、自動扶梯、傳送帶等開口部分,應將上下兩層連接為防火區,其硬快速卷簾門允許的較大建筑面積不應超過其建筑等級所規定的防火區建筑面積。
A balance needs to be struck between not affecting normal life and effective fire isolation. Generally speaking, high-rise buildings are equipped with openings such as connecting corridors, open staircases, escalators, and conveyor belts. The upper and lower floors should be connected to form a fire zone, and the large building area allowed by the hard and fast rolling shutter doors should not exceed the fire zone building area specified by their building level.
當上下開孔設有耐火極限大于3.00h的防火簾或水幕等隔離設施時,面積不得疊加計算。房間與中庭相通的大廳、通道,卷簾門應隔有B類防火門或耐火極限大于3.00h的防火卷簾門。
When there are isolation facilities such as fire curtains or water curtains with a fire resistance limit of more than 3.00h installed in the upper and lower openings, the area shall not be calculated by superposition. The lobby and passage connecting the room and atrium should be separated by Class B fire doors or fire resistant rolling shutter doors with a fire resistance limit greater than 3.00 hours.
由此可見,防火卷簾門廠家建議防火卷簾的空間設置需要一定的知識,不能隨便進行設計和安裝。火區設置的質量直接影響到人們的生命財產。
From this, it can be seen that the manufacturer of fireproof rolling shutter doors suggests that the space setting of fireproof rolling shutter requires certain knowledge and cannot be designed and installed casually. The quality of setting up a fire zone directly affects the safety of people's lives and property.
Thank you for reading. The source of this article is Jinan Electric Roller Shutter Door Installation and Maintenance. For more information and questions, please click: //domachine.com.cn We will continue to work hard to provide you with services. Thank you for your support!